Emblem Toilet Repair Parts
by Eljer
Keep your unique Eljer Emblem toilet working for years with the right replacement parts from your source, PlumbingSupply.com
®! Whether you need fill valves, flappers, or flush levers, you'll find them here. Looking for a replacement seat for your Emblem toilet? Click
our page.
Order replacement parts for the Emblem toilet tank numbers below:
141-1175
141-1180
141-1182
141-1185
141-4500
141-4903
Repair Parts for the Eljer Emblem Series Toilet
Models # 091-1500, 091-1520, 091-1560, 091-1570, 091-1580, 091-1590, 091-1605, 091-1615 & 091-1643
Tanks # 141-1175, 141-1180, 141-1182 & 141-1185
Not sure which model toilet you have? Try looking under the toilet tank lid or inside of the toilet tank.
Repair Parts for Eljer Emblem Toilets
Models # 091-4500, 091-4505, 091-4502, 091-4504, 091-4507, 091-4509, 091-5500 & 091-5505
Tanks # 141-4500 & 141-4903
Not sure which model toilet you have? Try looking under the toilet tank lid or inside of the toilet tank.
Related Items & Information
Eljer Toilet Parts By Series
Frequently Asked Questions
Q. "What does 'will fit' mean?"
A. "Will Fit" is a term used to define an item that may or may not be made by the original manufacturer (OEM), but will function just like the original part.
Q. "I installed a new fill valve and my new valve comes on (and then goes off) for a few seconds about once per hour?"
A. This could be caused by many things. The most common is with a Fluidmaster 400. This is a great valve but be sure to install the 1/4" tube per their instructions. Use the clip that comes with it and do not just stick it into the overflow tube or it will go on and off every so often by itself. If that isn't it, take some food coloring and place it in your tank. Wait a few hours and if some of the color has gone into the bowl then you probably need a new flapper.
Q. "My Universal Rundle toilet tank has a tilt valve. How does the Fluidmaster 400A fill valve allow the bowl to refill?"
A. If you are using a Fluidmaster 400A then you must also use the Fluidmaster #599 refill tube & clip. The clip attaches to the back of the tank and keeps the 1/4" refill tube pointed towards and into the overflow tube of the tilt valve. The 1/4" refill tube must not be attached directly into the overflow tube. There must be an air break between the refill tube and the overflow tube to keep the 400A from siphoning the water in the tank and putting it into the bowl continuously causing the 400A to turn on and off continuously.